Model 8800 NMHC NonMethane Hydrocarbon Analyzer
The Model 8800 NMHC is based on a flame ionization detector (FID) and catalyst. It is designed to measure the total, methane, and non-methane hydrocarbon content of gas samples. The analyzer can be configured with internal components for a single or multipoint analysis of ambient, non-condensing gas samples.
Automatic calibration
Electronic flow control of fuel, air & sample
Programmable virtual analog ranges
Automatic FID ignition

Model 8800 H Heated Total Hydrocarbon Analyzer
The Model 8800 H is based on a flame ionization detector (FID) and maintains the temperature of heated samples up to 200 °C. It has a dynamic range from less than 0.1 ppm to 100%. The analyzer is equipped with a generous complement of analog, digital, and logic output capabilities with room to expand.
Automatic calibration
Electronic flow control of fuel, air & sample
Sample pump starts automatically after warm-up
Programmable virtual analog ranges
Programmable relays
Automatic FID ignition

Model 8800 B Total Hydrocarbon Analyzer
The Model 8800 B is based on a flame ionization detector (FID), has a dynamic range from less than 0.1 ppm to 100%, and offers the best value in the series. The analyzer has a generous complement of analog, digital and logic output capabilities. It is configured for a single point analysis of non-condensing gas samples.
Automatic calibration
Programmable virtual analog ranges
Programmable relays
Automatic FID ignition
Quick connect electrical terminal block

Model 8800 A Total Hydrocarbon Analyzer
The Model 8800 A is based on a flame ionization detector (FID) and has a dynamic range from less than 10 ppb to 100%. The analyzer has a generous complement of analog, digital, and logic output capabilities with room to expand. It can be configured with internal components for a single or multipoint analysis of non-condensing gas samples.
Automatic calibration
Electronic flow control of fuel, air, and sample
Programmable virtual analog ranges
Programmable relays
Automatic FID ignition
Home

Model 8800 TCA Total Carbon Analyzer
The Model 8800 TCA is based on a flame ionization detector (FID) and methanizer. It is designed to measure total hydrocarbon content and a combined carbon monoxide (CO) and carbon dioxide (CO2) reading. The analyzer can be configured with internal components for a single or multipoint analysis of non-condensing, oxygen-free, inert gases.
Automatic calibration
Electronic flow control of fuel, air & sample
Programmable virtual analog ranges
Programmable relays
RS-485, RS-232 output
Automatic FID ignition

Model 8800 PID Total Volatile Organic Vapor Analyzer
The Model 8800 PID has a photoionization detector (PID) and an incredible dynamic range from 10 ppb to 1%. It is designed to analyze hundreds of volatile organic compounds (VOCs) and various other gases. The analyzer is relatively humidity insensitive and can be configured with internal components for a single or multipoint analysis of noncondensing gas samples.
Automatic calibration
Programmable virtual analog ranges
Programmable relays
RS-485, RS-232 output
Automatic calibration
Electronic flow control of fuel, air, and sample
Programmable virtual analog ranges
Programmable relays
Automatic FID ignition