Model 8800 PID Total Volatile Organic Vapor Analyzer The Model 8800 PID has a photoionization detector (PID) and an incredible dynamic range from 10 ppb to 1%. It is designed to analyze hundreds of volatile organic compounds (VOCs) and various other gases. The analyzer is relatively humidity insensitive and can be configured with internal components for a single or multipoint analysis of noncondensing gas samples.
Automatic calibration Programmable virtual analog ranges Programmable relays RS-485, RS-232 output
Automatic calibration Electronic flow control of fuel, air, and sample Programmable virtual analog ranges Programmable relays Automatic FID ignition
|
 |
Model 8800 TCA Total Carbon Analyzer The Model 8800 TCA is based on a flame ionization detector (FID) and methanizer. It is designed to measure total hydrocarbon content and a combined carbon monoxide (CO) and carbon dioxide (CO2) reading. The analyzer can be configured with internal components for a single or multipoint analysis of non-condensing, oxygen-free, inert gases.
Automatic calibration Electronic flow control of fuel, air & sample Programmable virtual analog ranges Programmable relays RS-485, RS-232 output Automatic FID ignition |
 |
Model 8800 NMHC NonMethane Hydrocarbon Analyzer The Model 8800 NMHC is based on a flame ionization detector (FID) and catalyst. It is designed to measure the total, methane, and non-methane hydrocarbon content of gas samples. The analyzer can be configured with internal components for a single or multipoint analysis of ambient, non-condensing gas samples.
Automatic calibration Electronic flow control of fuel, air & sample Programmable virtual analog ranges Automatic FID ignition |
 |
Model 8800 H Heated Total Hydrocarbon Analyzer The Model 8800 H is based on a flame ionization detector (FID) and maintains the temperature of heated samples up to 200 °C. It has a dynamic range from less than 0.1 ppm to 100%. The analyzer is equipped with a generous complement of analog, digital, and logic output capabilities with room to expand.
Automatic calibration Electronic flow control of fuel, air & sample Sample pump starts automatically after warm-up Programmable virtual analog ranges Programmable relays Automatic FID ignition |
 |
Model 8800 B Total Hydrocarbon Analyzer The Model 8800 B is based on a flame ionization detector (FID), has a dynamic range from less than 0.1 ppm to 100%, and offers the best value in the series. The analyzer has a generous complement of analog, digital and logic output capabilities. It is configured for a single point analysis of non-condensing gas samples.
Automatic calibration Programmable virtual analog ranges Programmable relays Automatic FID ignition Quick connect electrical terminal block
|
 |
Model 8800 A Total Hydrocarbon Analyzer The Model 8800 A is based on a flame ionization detector (FID) and has a dynamic range from less than 10 ppb to 100%. The analyzer has a generous complement of analog, digital, and logic output capabilities with room to expand. It can be configured with internal components for a single or multipoint analysis of non-condensing gas samples.
Automatic calibration Electronic flow control of fuel, air, and sample Programmable virtual analog ranges Programmable relays Automatic FID ignition
|
 |